What was found
AFT ENTRY DOORWAY AUXILIARY SILL CORRODED AT BURNDY BLOCK ATTACH AREA AT APPROXIMATELY BS. 990, STR. 21L. R&R INTERCOSTAL PER SRM.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT ENTRY DOORWAY AUXILIARY SILL CORRODED AT BURNDY BLOCK ATTACH AREA AT APPROXIMATELY BS. 990, STR. 21L. R&R INTERCOSTAL PER SRM.