What was found
FORWARD CABIN WET AREA FORWARD OF L1 DOOR CUTOUT FLOOR SUPPORT SURFACE CRACKED BETWEEN BS. 260 TO BS. 360, LBL 55. R&R FLOOR SUPPORT IAW SRM AND DWG.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FORWARD CABIN WET AREA FORWARD OF L1 DOOR CUTOUT FLOOR SUPPORT SURFACE CRACKED BETWEEN BS. 260 TO BS. 360, LBL 55. R&R FLOOR SUPPORT IAW SRM AND DWG.