What was found
FUEL FROM RIGHT MAIN TANK TRANSFERRED INTO CENTER TANK (CENTER PUMPS OFF, CROSSFEED CLOSED), 1600 LBS. IMBALANCE - RIGHT MAIN LOW, 1600 IN CENTER TANK. ABLE TO BURN DOWN CENTER TANK WITH PUMPS IN BUT WITH CENTER PUMPS OFF, RH MAINS OFF, CROSSFEED OPEN, FUEL STILL TRANSFERS FROM RIGHT MAIN INTO CENTER TANK. R&R NR 2 FUELING SHUT OFF VALVE PER AMM.