What was found
R1 LOWER MAIN SILL WEB ANGLE CORRODED AROUND FASTENER HOLES BETWEEN BS. 312 TO BS. 328, RBL 50. / R&R WEB ANGLE IAW SRM AND DWG.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
R1 LOWER MAIN SILL WEB ANGLE CORRODED AROUND FASTENER HOLES BETWEEN BS. 312 TO BS. 328, RBL 50. / R&R WEB ANGLE IAW SRM AND DWG.