What was found
AFT CARGO DOOR FLOOR TO SIDEWALL SUPPORT AT BS 767 - 773 RBL 25, HAD SURFACE CORROSION AROUND FASTENER HOLES. REMOVED DAMAGED FLOOR TO SIDEWALL SUPPORT. INSTALLED A NEW FLOOR TO SIDEWALL SUPPORT IAW SRM 51-40-02-0G-0 AND DWG 146A0081, SH 13, REV A. DAMAGE WAS FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2. NO DAMAGE LIMITS GIVEN, REPAIR BY REPLACEMENT IAW SRM 51-10-02-0G-0.