What was found
AFT CARGO BAY, BS 727B, RBL 8 FLOOR SUPPORT TO FRAME ATTACH FITTING WAS MISSING FOUR EACH. FASTENERS AND TWO EACH. FASTENER HOLES NOT DRILLED. LOCATED, DRILLED AND INSTALLED ACB FLOOR SUPPORT TO FRAME ATTACH FITTING IAW SRM 51-40-05, SRM 51-40-02, AND DWG 146A1201.