What was found
FLOOR STRUCTURE WEB - INTERCOSTAL CORRODED BETWEEN BS. 294.5 TO BS. 312, LBL 11.1, FORWARD GALLEY AREA. / R&R WEB INTERCOSTAL IAW SRM AND DWG.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOOR STRUCTURE WEB - INTERCOSTAL CORRODED BETWEEN BS. 294.5 TO BS. 312, LBL 11.1, FORWARD GALLEY AREA. / R&R WEB INTERCOSTAL IAW SRM AND DWG.