What was found
AFT PIT FLOOR TRACK STA 807+3" TO 807+6" RBL 13.8 WL 156 CORRODED AROUND NUTPLATE HOLES REMOVED CORROSION ON AFT PIT FLOOR TRACK STA 807+3 TO 807+6 RBL 13.8 IAW SRM 51-10-02 CONFIRMED WITH 10X MAG. MEASURED MATERIAL LOSS AT SPOT A TO BE .014" ORIGINAL .075 REMAINING .061 AND AT SPOT B LOSS OF .005 ORIGINAL .075 REMAINING .070, FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2, R&R DAMAGED FLOOR TRACK IAW SRM 53-00-53-2R-3. P/N 146A7501-31 ATAG WN7344