SUSPICIOUS ODOR REPORTED BY FLIGHT ATTENDANT IN / CABIN AROUND ROW 20. / PERFORMED SMOKE OR FUMES IN CABIN CONDITIONAL INSPECTION IAW AMM 05-51-56 AND FIM TASK / 21-00 TASK 806. OPENED COMPARTMENTS AND CEILING PANEL IN CABIN AREA 17/18/19/20/21/22 ABC / AND INSPECTED CABIN EQUIPMENT, ELECTRICAL CONNECTIONS AND DUCTS. FOUND BURN MARK AND ELECTRIC SMELL @ CEILING LIGHT BALLAST AND BULB @ 17/18/19DEF.R/R CEILING LIGHT/BALLAST ASSY @ 17/18/19 DEF