What was found
(SKYLINE DTIP) RH HORIZONTAL STAB, CRACK AT FIRST STIFFENER, LWR. I/B SIDE STA. 92.70 CUT OUT DAMAGE AREA. DIM: (.800"X.153"). AT. R/H HORIZ. STAB. FIRST STIFFENER. STA. 92.70. FABRICATED , LOCATED, DRILLED AND INSTALLED. T-ANGLE, AUGLE, SHIM. IAW B737SRM 55-10-09. (Y000419) NO FURTHER EVALUATION IS NECESSARY PER EA 1-751-1151