What was found
(SKYLINE DTIP) L/H HORIZ. STAB. CRACK ON THIRD STIFFENER, LWR. I/B SIDE STA. 92.70. CUTOUT DAMAGE AREA. DIM: (1.300" X .175") AT L/H HORIZ STAB THIRD STIFFENER STA 92.70 FABRICATED, LOCATED, DRILLED & INSTALLED T-ANGLE, ANGLE, SHIM IAW B737 SRM SRM 55-10-09. (Y000497) NO FURTHER EVALUATION IS NECESSARY PER EA 1-751-1151