What was found
BOTTOM TWO LAMPS ON AFT SERVICE DOOR THRESHOLD EMERGENCY EXIT LIGHT ASSEMBLY, AFT LAMP ON LEFT OVERWING DOOR EMERGENCY WINDOW LIGHT, AND SECOND BULB FROM TOP ON LEFT OVERWING EXIT DOOR INDICATOR LIGHT ASSEMBLY ARE INOP. RELAMPED AFT SERVICE DOOR THRESHOLD EMERGENCY EXIT LIGHT, L/H OVERWING DOOR EMERGENCY WINDOW LIGHT AND L/H OVERWING TOP EXIT DOOR INDICATOR. PERFORMED GOOD NEW LAMP TEST PER AMM 33-51-01-960-801. 92974U 16MAR20