What was found
PASSENGER CABIN, STA 500D+6, BL0, WL 208, FLOOR SUPPORT ANGLE IS CRACKED AT 2EA FLOOR PANEL HOLES. REMOVED FLOOR SUPPORT ANGLE @ STA 500A BL0 WL 208 IAW SRM 51-40-02-0G-0, VERIFIED NEW ANGLE AS P/N 143A5410-170 A-TAG A34417 IAW BOEING DWG 143A5400 REV: A, LOCATED AND DRILLED NEW ANGLE IAW SRM 51-40-05-0G-0, AND INSTALLED NEW FLOOR SUPPORT ANGLE @ STA 500D BL0 WL 208 IAW SRM 51-40-02-0G-0 AND BOEING DWG 143A5400 REV:D