What was found
DENT ON VERTICAL STAB L/E PANEL AT L/E STA 262 TRIMMED OUT THE DAMAGE PART OF THE SKIN ON VERTICAL STAB L/E PANEL AT L/E STA 262. DIMENSIONS 1.6" X 1.25" AND INSTALLED REPAIR DOUBLER IAW SRM 53-30-01-2R-1. 88920U 14 MAR 20
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DENT ON VERTICAL STAB L/E PANEL AT L/E STA 262 TRIMMED OUT THE DAMAGE PART OF THE SKIN ON VERTICAL STAB L/E PANEL AT L/E STA 262. DIMENSIONS 1.6" X 1.25" AND INSTALLED REPAIR DOUBLER IAW SRM 53-30-01-2R-1. 88920U 14 MAR 20