What was found
AFT CARGO BAY L/H FLOOR TO SIDEWALL SUPPORT PLATE HAS AREAS OF CORROSION AROUND NUTPLATE HOLES BS727 TO BS847 LBL21, WL156 EVALUATED CORROSION ON ACB L/H FLOOR TO SIDEWALL SUPPORT, REMOVED .020" FROM ORIG .040", FOUND TO BE OUT OF LIMITS, IAW SRM 53-00-53-1A-2. LOCATED AND DRILLED NEW, FLOOR TO SIDEWALL SUPPORT, AND INSTALLED, IAW SRM 51-40-05-0G-0, DWG 146A7500, SRM 51-40-02-0G-0.