What was found
RUST ON FLOOR DOOR MOUNTED EVACUATION SLIDE BRACKE HARDWARE OF AFT SERVICE DOOR AT AFT GALLEY AREA REPLACED HARDWARE ON FLOOR DOOR MOUNTED EVACUATION SLIDE BRACKET OF AFT SERVICE DOOR AT AFT GALLEY AREA IAW AMM 25-66-02-400-801 STEP 3D1(G)