What was found
***CORROSION*** ON FORWARD CARGO BAY FLOOR TO SIDEWALL SUPPORT AT B .S. 500A-500D, R.B.L. 22, W.L. 155 REMOVED CORRODED FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT AT BS 500A-500D RBL 22 WL 155 AND REPLACED WITH NEW IAW SRM 51-40-05, SRM 51-40-02, DWG 143A7902, DWG 143A7500, SRM 53-00-53-1A-2, SOPM 20-41-02, SRM 51-20-01-0G-0. 92954U 03/14/20.