What was found
RIGHT AND LEFT OVERWING EMERGENCY EXIT WINDOW LIGHTS INOP. / REMOVED AND REPLACED INOP FUSE IN M1669 AND M1668 EMERGENCY LIGHTS BATTERY CHARGER (POWER SUPPLY). PER AMM 33-51-06-960-804 STEP.3.D. (1 THRU 3). PERFORMED GOOD OPS TEST PER AMM 33-51-06-960-804 STEP. 3.D.(4.). RIGHT AND LEFT OVERWING EMERGENCY EXIT WINDOW LIGHT NOW FULLY OPERATIONAL.