What was found
***CORROSION*** CORROSION ON MULTIPLE AREAS OF FLOOR TO SIDEWALL SUPPORT FROM BS 440 TO BS 500B; LBL 24; WL 156 / REMOVED F.C.B. BULKHEAD FLOOR SUPPORT B/S396 LBL24. RBL24 W.L.156 FDR ACCESS IAW. SRM 51-40-02-0G-0 REMOVED SIDEWALL SUPPORT FCB. FROM B/S396 TO B/S500D LBL24 WL156 IAW SRM 51-40-02-0G FABRICATED LOCATED AND DRILLED FLOOR TO SIDEWALL SUPPORT B/S 396-500 LBL24 WL156 FROM BAC1496-444 #7075T6 LOT#142869 PER DWG SRM 51-40-05 & DWG 5754899U27 AND DWG 143A7501 REV B & INSTALLED NEW SPLICE AND ALL REPAIR PARTS IAW SRM 53-00-53-2R-6 PARA 4-D FIG.202 4-9-2020 54826U