As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
HOLE FRAME ON BS 1016 DIAMETER OF HOLE 7R AT STRG 3R IS OUT OF TOLERANCES REQUIRED IN SI CARD Ï¿½ 12107- 53 STEP 24.D AT BS 1016 PRESSURE BULKHEAD AT AFT GALLEY AREA / PERFORMED REPAIR ON HOLE 7R AT STR 3R IAW SI 12107-53 STEP 25; ITEM A TO ITEM B PAGE 50