What was found
FWD CARGO PIT R/H Z ANGLE BETWEEN STA 500A +10' TO STA 500C +16' RBL 24' WL 155 HAS CORROSION ON UPPER SURFACE / REMOVED CORROSION FROM FWD CARGO COMPARTMENT Z-ANGLE BETWEEN STA 500A+10 TO STA 500C+16 RBL 24 WL 155 ORIGINAL THICKNESS .040' REMOVED .008 REMAINING .032' FOUND TO BE OUT OF LIMITS I/A/W SRM 53-00-53-1A-2 FABRICATED REPLACEMENT Z-ANGLE P/N 143A7501-4 AND INSTALLED REPLACEMENT Z-ANGLE I/A/W BOEING DRAWING 143A7501 AND 143A7500 REV A AND SRM 51-40-02-0G-0 A-TAG A21658