What was found
CABIN FLOOR RIGHT CREASE BEAM WEB STA 727D+6' RBL 68.5 WL 208 LOWER SURFACE HAS CORROSION JUST OUTBOARD OF LIGHTNING HOLE. BLENDED CORROSION ON RT CREASE BEAM WEB PN 146A5925-24 AT STA 727D+6' RBL 68.5 WL208. LOWER SURFACE ORIGINAL THICKNESS .036', LOSS .005', REMAINING .031' FOUND OUT OF LIMITS IAW SRM 53-60-13-1A-1 FIG 103 DETAIL C. REMOVED, FABRICATED AND INSTALLED NEW WEB IAW SRM 51-40-02-0G-0 AND DRAWING 146A5900. WEB WAS FORMED AND HEAT TREATED ON WORK ORDER 40849-2700-0001 PN 146A5925-24.