What was found
CORROSION ON TOP OF FLOOR ANGLE AROUND NUT PLATE FASTENERS AT FS 270 BETWEEN LBL 4 AND RBL 10. REPAIRED PER EA 1-A53-13812 FLOOR ANGLE PN 141A5213-6.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION ON TOP OF FLOOR ANGLE AROUND NUT PLATE FASTENERS AT FS 270 BETWEEN LBL 4 AND RBL 10. REPAIRED PER EA 1-A53-13812 FLOOR ANGLE PN 141A5213-6.