What was found
CORROSION FOUND ONE FLOOR SUPPORT AT BS 627.5 +10, RBL 64, WL 208. REMOVED AND REPLACED BS 627.5 - 663.25+9 IAW SRM 51-40-02-0G-0, AND DWG 144A5901.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION FOUND ONE FLOOR SUPPORT AT BS 627.5 +10, RBL 64, WL 208. REMOVED AND REPLACED BS 627.5 - 663.25+9 IAW SRM 51-40-02-0G-0, AND DWG 144A5901.