What was found
FOUND DENT AT FUSELAGE SKIN STA 905+10' AND STR 22R / EVALUATED DENT FOUND OUT OF LIMITS. CUT OUT DAMAGE. DIMENSION 4' X 2 3/4' AT FUSELAGE SKIN BETWEEN BS 911 AND BS 923 STR 22R. REMOVED FASTENERS ON DAMAGE AREA. PERFORMED HFEC, ROTARY INSP, PERFORMED INSURANCE CUTOUT. FABRICATED AND INSTALLED FILLER AND DOUBLER REPAIR PARTS IAW SRM 53-00-01-2R-1, REPAIR 1, AND SRM 51-40-02-0G-0.