What was found
CORROSION ON FLOOR TO SIDEWALL SUPPORT AT AFT CARGO BAY BS727 - BS807 LBL21 WL157. REMOVED CORROSION ON MULTIPLE SPOTS LARGEST AREA MEASURED 1.5'L X .9'W AND 0.004' DEEP. ORIGINAL THICKNESS OF 0.040' FLOOR TO SIDEWALL SUPPORT L/H BS727-807; LBL21 FOUND TO BE OUT OF LIMITS PER 53-00-53-1A-2 4.A.(2) FIG 103 DETAIL E. REMOVED FLOOR TO SIDEWALL SUPPORT L/H BS727-807; LBL21 PER SRM 51-40-02-0G-0; INSTALLED NEW FLOOR TO SIDEWALL SUPPORT L/H BS727-807; LBL21 PER SRM 51-40-02-0G DWG 146A7500 AND SPLICE REPAIR AT BS727E+10' LBL21 PER SRM 53-00-53-2R-6 93114U 26JUL20