CRACKED FLOORBEAM, BS 540, BL 0 - LBL 24.5, WL 208.1. REMOVED THE CABIN FLOORBEAM IAW SRM 51-40-02-0G-0. LOCATED AND DRILLED A NEW FLOORBEAM ANGLE IAW SRM 51-40-05-0G-0, AND DWG 143A5240, REV-B. AND INSTALLED THE NEW FLOORBEAM IAW SRM 51-40-02-0G-0, AND DWG 143A0060, REV-B.