What was found
***CORROSION*** IN AFT CARGO BAY ON FLOOR TO SIDEWALL SUPPORT AT B.S. 727-767; R.B.L. 21; W.L. 154. / REMOVED ACB SIDEWALL SUPPORT BS727-767 RBL21 RECEIVED NEW SIDEWALL SUPPORT LOCATED; DRILLED; COUNTERSUNK SIDEWALL SUPPORT INSTALLED NEW ACB SIDEWALL SUPPORT BS727-762 RBL21 IAW SRM 51-40-02; SRM 51-40-08; SRM 51-40-05; DWG# 146A0061; DWG# 146A7500 7191U 15JUL20 CORROSION ON AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT AT BS727-767; RBL21; WL154 WAS FOUND OUT OF LIMITS DUE TO PROXIMITY TO HOLES PER SRM 53-00-53-1A-2 FIG 103; DETAIL D.