What was found
LH AC BAY AFT WALL VAPOR BARRIER CRACKED. LENGTH OF CRACK APPROXIMATELY 6' IN LENGTH. / LH AC BAY AFT WALL VAPOR BARRIER CRACKED. LENGTH OF CRACK APPROXIMATELY 6' IN LENGTH.COMPLIED WITH EA 1-A57-13410. THIS IS A TIME LIMITED DEFERRAL AND REINSPECT EVERY 100 CYCLES. COMPLY WITH PERMANENT REPAIR WITHIN 600 CYCLES.REMOVE ALUMINUM FOIL SPEED TAPE AND INSPECT CRACK(S)FOR ADDITIONAL GROWTH. IF NO ADDITIONAL GROWTH; REAPPLY SPEED TAPE. IF CRACK HAS GROWN BUT IS STILL WITHIN THE LIMITS OF STEP 1 OF THIS EA; STOP DRILL THE CRACK PER 737-700/800 SMR 51-10-02 AND APPLY SPEED TAPE.ACCOMPLISH A PERMANENT REPAIR AS GIVEN IN 737-700/800 SRM 51-70-04; REPAIR 10 OR AS AN ALTERNATIVE; REPAIR PART OF THE CRACK SO THAT THE CRACK LENGTH IS LESS THAN OR EQUAL TO THE MAXIMUM ALLOWABLE DAMAGE LIMIT. APPLY THE INTERIM SEAL OVER THE CRACK THAT IS LEFT AS GIVEN IN 737-700/800 SRM 57-10-10 PARAGRAPH 2.C.(4) / ALLOWABLE DAMAGE 2