What was found
FWD PIT RIGHT Z ANGLE UPPER SURFACE CORRODED IN SEVERAL AREAS FROM STA 500A TO 500I RBL 24 AND WL 155. REMOVED CORROSION & EVALUATED ON FWD PIT RT Z ANGLE STA 500A - 500I RBL 24 WL 155 AS OUT OF LIMITS IAW SRM 51-10-02-0G-0 & SRM 53-00-00-53-1A-2. REMOVED OUT OF LIMITS Z ANGLE SECTION FROM STA 500B+12' - 500I. VERIFIED NEW Z-ANGLE AS PN BAC1446-444 7075 T62 ATAG #A57840 IAW SRM 53-00-53-2R-5. LOCATED & DRILLED REPAIR PARTS IAW SRM 53-00-53-2R-5 STEPS 4 (D TO H). TREATED AND PRIMED IAW SRM 53-00-53-2R-5. INSTALLED Z-ANGLE; SPLICE; AND REPAIR PARTS. SPLICE LOCATED AT STA 500B+12' IAW SRM 53-00-53-2R-5. APPLIED CIC IAW SRM 53-00-53-2R-5 P/N 143A7501-188