What was found
MAIN CABIN FLOOR BEAM INTERCOSTAL CRACKED AT STA. 540 RBL. 2'. REMOVED OLD INTERCOSTAL AND INSTALLED NEW INTERCOSTAL PER SRM 51-40-02-0G-0. REINSTALLED FLOOR PANEL 231XF PER AMM 53-21-00.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MAIN CABIN FLOOR BEAM INTERCOSTAL CRACKED AT STA. 540 RBL. 2'. REMOVED OLD INTERCOSTAL AND INSTALLED NEW INTERCOSTAL PER SRM 51-40-02-0G-0. REINSTALLED FLOOR PANEL 231XF PER AMM 53-21-00.