As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
EXIT SIGN ABOVE AFT ENTRY DOOR IS INOP. PERFORMED CONTINUITY TEST FROM CONNECTOR D2982 TO D10744 AND GROUND, PER WDM 33-51-14 AND FOUND WIRE W3142-0474-20 DISCONNECTED FROM GD3814-DC. TERMINATED AND REINSERTED WIRE W3142-0474-20 INTO GD3814-DC AND PERFORMED GOOD CONTINUITY CHECK, PER SWPM 20-90-15 AND WDM 33-51-14. PERFORMED GOOD FUNCTIONAL TEST OF EMERGENCY EXIT LIGHTS ABOVE AFT LT DOOR, PER AMM 33-51-00-710-801 59019U 14SEP20.