What was found
FLOOR PANEL SUPPORT IS CRACKED AT BS 540 BETWEEN BL 0-LBL 24.5 WL 208 / RMEOVED AND REPLACED CRACKED FLOOR PANEL SUPPORT AT BS 540 BETWEEN 0.0 LBL - 24.5. WL 208 IAW DWG 143A0060
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOOR PANEL SUPPORT IS CRACKED AT BS 540 BETWEEN BL 0-LBL 24.5 WL 208 / RMEOVED AND REPLACED CRACKED FLOOR PANEL SUPPORT AT BS 540 BETWEEN 0.0 LBL - 24.5. WL 208 IAW DWG 143A0060