What was found
CORROSION, ON FRAME IN MULTIPLE AREAS AT AFT CARGO BAY BS 947 LBL 11 TO RBL 18 WL 178. CORROSSION ON FRAME FOUND TO BE OUT OF LIMITS, DUE TO PROXIMITY TO FASTENER HOLES REMOVED FRAME. LOCATED DRILLED & INSTALLED NEW FRAME, PER SRM 51-40-02-0G-0; SRM 51-40-05-0G-0 DWG 147A1047; 147A7500; DWG 147A0002.