What was found
LEFT HAND PACK BAY, HORIZONTAL ANGLE COMMON TO LOWER SIDE OF CENTER FUEL TANK AT STATION 663 IS CRACKED 3RD FASTENER OUTBOARD OF KEEL BEAM VERTICAL ANGLE, MARKED. REMOVED DAMAGED SECTION OF HORIZONTIAL ANGLE COMMON TO LOWER SIDE OF CENTER FUEL TANK AT STA 663 AND 3RD FASTENER OUTBOARD OF KEEL BEAM VERTICAL ANGLE IN LEFT HAND PACK BAY AND REPAIRED, IAW SRM 57-10-10-2R-5. ACCOMPLISHED LEAK CHECK OF FASTENERS COMMON TO FUEL TANK, NO LEAKS NOTED.