What was found
CORROSION FOUND AFT CABIN FLOOR STRUCTURE AT STA 947.5 +12 RBL 46 & WL 208.1. REMOVED AND REPLACED CORRODED FLOOR STRUCTURE SUPPORT AT STA 947.5+12 RBL 46, PER REF SRM 51-40-02-0G-0 AND DRAWING NR 147A5760.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION FOUND AFT CABIN FLOOR STRUCTURE AT STA 947.5 +12 RBL 46 & WL 208.1. REMOVED AND REPLACED CORRODED FLOOR STRUCTURE SUPPORT AT STA 947.5+12 RBL 46, PER REF SRM 51-40-02-0G-0 AND DRAWING NR 147A5760.