What was found
ENROUTE FROM DEN-MDW FUEL GUAGES SHOWED IMBALANCE 600 HEAVY ON RIGHT, REBALANCED THE RIGHT. DURING REL ENT CURVES SHOWED GOOD IMBALANCE HEAVY ON LEFT, REBALANCED AGAIN. LANDED WITH CLOSE TO PLANNED FUEL. PERFORMED TAN AND COMPENSATOR UNITS WET CAPACITANCE CHECK ON NR 1 AND NR 2 FUEL TANKS, FOUND NR 1 TANK COMPENSATORS NR F11 AND F12 OUT OF RANGE. NR 2 TANK COMPENSATORS ARE NORMAL, REF AMM 28-41-21. OK TO CONTINUE, PER MEL 28-6-02 SP NR 1; SP NR 3; SP NR 28 CAPPED AND STOWED NR 1 TANK F1 15 CONNECTOR D11312 TRACKING NR 58772.