What was found
CRACK WEB-INTERCOSTAL FLOOR STRUCTURE LOCATED BS 344 TO BS 360 AND BL 0 FWD GALLEY AND LAV (1 EA). REMOVED AND REPLACED WEB-INTERCOSTAL LOCATED BETWEEN BS 344 TO BS 360 AND BL 0 FLOOR STRUCTURE FWD GALLEY AREA, IAW B737-700 SRM 51-40-02 SRM 51-10-02 DRAWING NR 141A5400 SHEET 40 REV-, DUE TO NOT FOUND ALLOWABLE DAMAGE IN SRM PART NUMBER OF WEB INTERCOSTAL, USED P/N 141A5410U150.