What was found
CRACK WEB, INTERCOSTAL FLOOR STRUCTURE LOCATED BETWEEN BS 344 AND BS 360 LBBL 12 FWD GALLEY AND LAV. REPLACED WEB-INTERCOSTAL FLOOR STRUCTURE LOCATED BETWEEN BS 344 AND BS 360 LBBL 12 FWD GALLEY, IAW B737-700 SRM 51-40-02-0G-0 DWG NR 141A5400 SHEET NR 46 REV A AND SRM 51-10-02 ITEM 9 MEASURES OF CRACK ARE: L=0.316' TOOL USED CALIPER P/N 500-197-30 S/N A16164995 DUE DATE 04NOV21.