What was found
CRACKED STRINGER AT AREA AFT OF FWD CARGO BAY BS 540 S26R WL 156. REMOVED CRACKED SECTION OF STR 26R, BS 540-520D+12' WL 156. LOCATED; DRILLED AND INSTALLED STR 26R REPAIR, PER SRM 53-00-03-2R-1 FIG 204 1.- 4.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.