What was found
FWD GALLEY FLOOR STRUCTURE STA. 274 TO 294 RBL. 1; INTERCOSTAL CRACKED AT FASTENER HOLE / REMOVED DAMAGED INETCOASTAL AND INSTALLED NEW INTERCOASTAL I/A/W SRM 51-40-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD GALLEY FLOOR STRUCTURE STA. 274 TO 294 RBL. 1; INTERCOSTAL CRACKED AT FASTENER HOLE / REMOVED DAMAGED INETCOASTAL AND INSTALLED NEW INTERCOASTAL I/A/W SRM 51-40-02.