What was found
AFT CARGO BAY; R/H FLOOR TO SIDEWALL SUPPORT PLATE AS AREAS OF CORROSION AROUND NUT PLATES BS727+10 TO BS767 RBL23 WL156 / EVALUATED CORROSION ON ACB RH FLOOR TO SIDEWALL SUPPORT; BS727-767; REMOVED .015' FROM ORIG .040'; FOUND TO BE OUT OF LIMITS; IAW SRM 53-00-53-1A-2. REMOVED DAMAGED SUPPORT; LOCATED; DRILLED; AND INSTALLED NEW FLOOR TO SIDEWALL SUPPORT; BS727-767; ALL IAW SRM 51-40-05-0G-0; SRM 51-40-02-0G-0; DWG 146A7500.