As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
R/H SIDE OVERWING EXIT; EMERG. EXIT SIDEWALL LIGHT INOP / REMOVED AND REPLACED SIDEWALL EMERGENCY EXIT LIGHT AND F1 POWER SUPPLY FUSE AND PERFORMED GOOD OPERATIONAL TEST OF SIDEWALL EMERGENCY EXIT LIGHT PER WDM 33-51-11 WDM 33-51-13; WDM 33-51-21; AMM 33-51-06-960-804; AMM 33-51-01-960-802; AMM 33-51-00-720-801. 81136U 31JAN21 56576R 31JAN21