What was found
CRACK SERVICE DOOR CUT OUT ON STUD FRAME LOCATED BS294.5 BETWEEN STR8R AND STR9R AT FWD GALLEY AREA / REPLACED STUD FRAME ON SERVICE DOOR CUT OUT LOC ON BS294.5 BTW STR 8R AND STR 9R AT FWD GALLEY AREA IAW B737-700 SRM 51-10-02 ITEM 9 AND DWG # 141A8370 REV C