What was found
CRACK INDICATION ON FWD SERVICE DOOR LOC. ON BEAM #4 AND 14 INCH AFT FWD LEADING EDGE DOOR INTERNAL AREA I/B SIDE AT PASSENGER CABIN (1 EA) (LENGTH = 1.750 INCH APPROX.) / REPLACED BEAM ON FWD SERVICE FOOR LOC AT 14 INCH AFT OF FWD LEADING EDGE DOOR INTERNAL AREA I/B SIDE AT PASSENGER CABIN IAW DWG 141A6535 REV B AND WORK INSTRUCTION # 5241-C-14093-NG ITEM 2(B) AND SRM 51-40-02 PART NUMBER USED 141A6536U20 BATCH 2020001281 PO-000