CORROSION ON AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT BS 727 TO BS 767 RBL 23 WL 156 / CORROSION ON FLOOR TO SIDEWALL SUPPORT WAS FOUND TO BE OUT OF LIMITS DUE TO PROXIMITY TO FASTENER HOLES PER SRM 53-00-53-1A-2 REMOVED AND REPLACED SUPPORT PER: SRM 51-40-02 AND DRAWING 146A7500. AND AS PER EA 21-153-00319 REV IR AND ATS ER 21-01194 REV IR