As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
***CORROSION*** ON RAIL AROUND FASTENER HOLE BS727B+3 LBL3 WL156. / PERFORM CUT-OUT FROM BS727+7' TO BS 727B+10' LBL3 WL156 I.A.W SRM 53-00-53-2R-2 STEP 2.F. LOCATED; DRILLED AND COUNTERSANK NEW REPAIRABLE BEAM AND CHANNEL SPLICE I.A.W SRM 53-00-53-2R-2; SRM 51-40-05; AND SRM 51-40-08; APPLIED CHEMICAL CONVERSION COATING AND PRIMER I.A.W SRM 51-40-02-0G-0 AND DWG 146A0061 REV:A AND SRM 53-00-53-2R-2