As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CORROSION ON RT OVERWING EMERGENCY EXIT LOWER SILL BS619 - BS636 RBL71 WL222. MARKED / REMOVED CORROSION ON RT OVERWING EMERGENCY EXIT LOWER SILL BS.619-BS.636 RBL 71 WL 222; FOUND TO BE OUT OF LIMITS DUE TO LOCATION OF BLEND WITHIN 1' OF DRAIN HOLE ON LWR SILL; REMOVED AND REPLACED LOWER SILL WEB PER SRM 53-40-15-1A-1; SRM 51-40-02; AND DWG 144A8201 SH.4.