What was found
CRACK ON FRAME AT RADIUS ABOVE FWD ENTRY DOOR BS312 11' BELOW S-4L WL283. MARKED / REMOVED DAMAGE FROM FRAME AT RADIUS ABOVE FWD ENTRY DOOR BS 312; 11' BELOW S-4L WL 283; REMOVED AREA IS 0.3' X 0.2'; HFEC INSPECTION PERFORMED; NO CRACKS FOUND; APPLIED CHEMICAL CONVERSION COATING AND PRIMER IAW SRM 51-10-02 AND SOPM 20-41-02. DAMAGE REMOVAL AND REPAIR IS ACCOMPLISHED ON EA 21-153-00547 REV IR AND ATS ER 21-01377 REV IR 49570U 07MAR21 LEAD 838 07MAR21