As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FWD CARGO COMPT. FLOOR PANEL120DF EDGE HAS CORROSION / VERIFIED CORROSION DAMAGE TO BE 48' IN LENGTH LIMIT = 20' IN LENGTH PANEL 120DF IS OUT OF LIMITS IAW SRM 53-00-53-1A-1 FIG 102 FABRICATED NEW PANEL IAW AMM 25-52-01-201-801 AND B 737-800 DWG 453A1610 REV F TREATED AND PRIMED LOWER SURFACE OF PANEL IAW AMM 51-21-41-370-801 AND AMM 51-21-72-370-804